beautypg.com

Distributed by: technical specifications chart – IOTA DLS-240-27-40 User Manual

Page 4

background image

Distributed By:

TECHNICAL SPECIFICATIONS CHART

68357-227 REV 030613

IOTA ENGINEERING PO BOX 11846 TUCSON, AZ 85734 TEL: 1-800-866-IOTA (4682) FAX: (520) 741-2837 WEB: www.iotaengineering.com

DC Output Voltage (No Load) approx.

Output Voltage Tolerance (No Load)

Output Amperage, Max Continuous

Output Voltage (Full Load) approx.

Maximum Power Output, Continuous

Ripple and Noise

Input Voltage Range

Input Voltage Frequency

Maximum AC Current (@216Vac)

Typical Efficiency

Max Inrush Current, Single Cycle

Short Circuit Protection

Overload Protection

Line Regulation

Load Regulation

Fan Control

Thermal Protection

Working Temperature Range

Storage Temperature

Withstand Voltage (VDC)**

Approximate Dimensions

Weight

27.2V (DC)

+ or - .7%

40 Amps

>27.0V (DC)

1100 Watts

<100 mV rms

200-240 AC

47-63

10.0 Amps

>80%

40 Amps

Yes

>100%

100 mV rms

<1%

PROPORTIONAL

YES

0° - 40° C

-20° to 80° C

1700/1700/500

13

″ x 6.5″ x 3.4″

7.8 lbs

DLS-240-27-40*

RATINGS AND SPECIFICATIONS

**

Primary to Chassis/Primary to Secondary/Secondary to Chassis

*

Unit is not UL Listed

27.2V (DC)

+ or - .7%

25 Amps

>27.0V (DC)

675 Watts

<100 mV rms

200-240 AC

47-63

6.0 Amps

>80%

30 Amps

Yes

>100%

100 mV rms

<1%

PROPORTIONAL

YES

0° - 40° C

-20° to 80° C

1700/1700/500

9.7

″ x 6.7″ x 3.4″

5.0 lbs

DLS-240-27-25

This manual is related to the following products: