Typical wiring diagrams, Page 4, I-13-em-b – IOTA I-13-EM-B User Manual
Page 4

Page 4
UNIT
CONNECTOR
CHARGE
INDICATOR
TEST
SWITCH
RED OR
RED/BLK (+)
WHT/BLK
BLK (120V)
ORG (277V)
WHITE
BLUE/WHT
BLUE
YELLOW
YEL/BLK
BLUE
BLACK
UNSWITCHED LINE
COMMON
SWITCHED OR
UNSWITCHED
LINE
➀
➁
A.C.
BALLAST
*LAMP
WHT/RED
WHT/BLK
FIXTURE
GROUND
EMERGENCY
BALLAST
ONE LAMP MAGNETIC BALLAST
1LMBB
*AC/EMERGENCY LAMP
➂
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
➀
➁
➂
TYPICAL WIRING DIAGRAMS
For use with 2 pin, 5 through 13 watt lamps with integral starter only
Rev. 071513
68313-202
1. ONE LAMP MAGNETIC BALLAST
3. ONE LAMP ELECTRONIC BALLAST
5. TWO LAMP PARALLEL MAGNETIC BALLAST
7. TWO LAMP SERIES MAGNETIC BALLAST
2. ONE LAMP HIGH POWER FACTOR MAGNETIC BALLAST
4. TWO LAMP ELECTRONIC BALLAST
6. TWO LAMP PARALLEL HIGH POWER FACTOR MAGNETIC BALLAST
8. TWO LAMP SERIES HIGH POWER FACTOR MAGNETIC BALLAST
BLK (120V)
ORG (277V)
WHITE
WHITE
BLUE/WHT
BLUE
YELLOW
YEL/BLK
BLUE
BLACK
UNSWITCHED LINE
SWITCHED OR
UNSWITCHED
LINE
➀
A.C.
BALLAST
*LAMP
TEST
SWITCH
COMMON
UNIT
CONNECTOR
CHARGE
INDICATOR
RED OR
RED/BLK (+)
WHT/BLK
➁
WHT/RED
WHT/BLK
FIXTURE
GROUND
EMERGENCY
BALLAST
1LHPFMBB
ONE LAMP HIGH POWER FACTOR MAGNETIC BALLAST
*AC/EMERGENCY LAMP
➂
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
➀
➁
➂
BLK (120V)
ORG (277V)
WHITE
WHITE
BLUE/WHT
BLUE
YELLOW
YEL/BLK
BLUE
RED
BLACK
UNSWITCHED LINE
SWITCHED OR
UNSWITCHED
LINE
➀
A.C.
BALLAST
*LAMP
TEST
SWITCH
COMMON
UNIT
CONNECTOR
CHARGE
INDICATOR
RED OR
RED/BLK (+)
WHT/BLK
➁
WHT/RED
WHT/BLK
FIXTURE
GROUND
ONE LAMP ELECTRONIC BALLAST
EMERGENCY
BALLAST
1LEBB
➂
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
➀
➁
➂
BLK (120V)
ORG (277V)
WHITE
WHITE
WHT
BLUE/WHT
BLUE
YELLOW
YEL/BLK
WHITE
BLACK
BLACK
BLACK
UNSWITCHED LINE
SWITCHED OR
UNSWITCHED
LINE
➀
A.C.
BALLAST
*LAMP
LAMP
*AC/EMERGENCY LAMP
TEST
SWITCH
COMMON
UNIT
CONNECTOR
CHARGE
INDICATOR
RED OR
RED/BLK (+)
WHT/BLK
➁
WHT/RED
WHT/BLK
FIXTURE
GROUND
EMERGENCY
BALLAST
2LEBB
TWO LAMP ELECTRONIC BALLAST
➂
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
➀
➁
➂
BLK (120V)
ORG (277V)
WHITE
RED
BLUE
YELLOW
YEL/BLK
BLUE
BLACK
UNSWITCHED LINE
SWITCHED OR
UNSWITCHED
LINE
➀
A.C.
BALLAST
*LAMP
LAMP
*AC/EMERGENCY LAMP
TEST
SWITCH
BLUE/WHT
COMMON
UNIT
CONNECTOR
CHARGE
INDICATOR
RED OR
RED/BLK (+)
WHT/BLK
➁
WHT/RED
WHT/BLK
FIXTURE
GROUND
TWO LAMP PARALLEL MAGNETIC BALLAST
EMERGENCY
BALLAST
2LPMBB
➂
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
➀
➁
➂
BLK (120V)
ORG (277V)
WHITE
WHITE
BLUE
BLUE/WHT
BLUE
YELLOW
YEL/BLK
BLUE
BLACK
UNSWITCHED LINE
SWITCHED OR
UNSWITCHED
LINE
➀
A.C.
BALLAST
*LAMP
LAMP
*AC/EMERGENCY LAMP
TEST
SWITCH
COMMON
UNIT
CONNECTOR
CHARGE
INDICATOR
RED OR
RED/BLK (+)
WHT/BLK
➁
WHT/RED
WHT/BLK
FIXTURE
GROUND
EMERGENCY
BALLAST
2LPHPFMBB
TWO LAMP PARALLEL HIGH POWER FACTOR MAGNETIC BALLAST
➂
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
➀
➁
➂
BLK (120V)
ORG (277V)
WHITE
WHT
BLUE/WHT
BLUE
YELLOW
YEL/BLK
BLUE
BLACK
UNSWITCHED LINE
SWITCHED OR
UNSWITCHED
LINE
➀
A.C.
BALLAST
*LAMP
LAMP
*AC/EMERGENCY LAMP
TEST
SWITCH
COMMON
UNIT
CONNECTOR
CHARGE
INDICATOR
RED OR
RED/BLK (+)
WHT/BLK
➁
WHT/RED
WHT/BLK
FIXTURE
GROUND
TWO LAMP SERIES MAGNETIC BALLAST
2LSMBB
EMERGENCY
BALLAST
➂
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
➀
➁
➂
BLK (120V)
ORG (277V)
WHITE
WHITE
RED
BLUE/WHT
BLUE
BLUE
BLACK
UNSWITCHED LINE
SWITCHED OR
UNSWITCHED
LINE
➀
A.C.
BALLAST
LAMP
*AC/EMERGENCY LAMP
TEST
SWITCH
COMMON
CHARGE
INDICATOR
RED OR
RED/BLK (+)
WHT/RED
FIXTURE
GROUND
UNIT
CONNECTOR
WHT/BLK
YELLOW
YEL/BLK
➁
*LAMP
WHT/BLK
EMERGENCY
BALLAST
2LSHPFMBB
TWO LAMP SERIES HIGH POWER FACTOR MAGNETIC BALLAST
➂
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
➀
➁
➂
I-13-EM-B
I-13-EM-B
I-13-EM-B
I-13-EM-B
I-13-EM-B
I-13-EM-B
I-13-EM-B
I-13-EM-B
Wiring and Troubleshooting Tips are available on-line at http://www.iotaengineering.com/wiringtips.pdf