beautypg.com

Hall Research VSM-I-A-4-JA4 User Manual

Page 9

background image

Genesis™ Series 4x4 AV Matrix Switches

7

URA does not have RGB Skew correction so you would need to use low-

skew UTP cable for that option if the distance is over 200 ft. The URA-SKU,

or URA-XT, both have RGB skew correction so you can use any Cat5e or

Cat6 cable regardless of length

Similar to the audio input, the audio outputs are also balanced. So when

connecting to balanced devices use both + and – terminals. But if you are

connecting the output to unbalanced sinks (such as using 3.5mm mini-stereo

plugs),

do not

connect the unused outputs to ground. You can connect the

tip and ring to either + sides or the – sides, as shown below.

Figure 4 –

Connecting balanced audio outputs to

unbalanced devices

If the matrix needs to be controlled via RS-232, plug the controller (or PC) to

the DB9 Female port on the rear of the matrix. Connection to PC’s DB9 Male

is made using a straight through DB9 Male-to-Female cable (as shown

below).

DB9-Female on Matrix

Controller DB9-Male

Pin Function

Pin Function

2

TX (output)

2

RX (input)

3

RX (input)

3

TX (output)

5

Ground

5

Ground

Table 2 – RS-232 Control Port Pinout

Note on RS-232 port availability on PC

Most PCs do not have a serial port, so you may need

a USB to RS-232 Serial converter. These are available

from Hall Research (Model USB-RS232-1).

The 4x4 VSM matrix is available with IP port (VSM-I- …). On these units

there is an RJ45 (10/100 Base-T) for connection to your Local Area Network.

This manual is related to the following products: