Hall Research VSM-I-A-4-JA4 User Manual
Page 9

Genesis™ Series 4x4 AV Matrix Switches
7
URA does not have RGB Skew correction so you would need to use low-
skew UTP cable for that option if the distance is over 200 ft. The URA-SKU,
or URA-XT, both have RGB skew correction so you can use any Cat5e or
Cat6 cable regardless of length
Similar to the audio input, the audio outputs are also balanced. So when
connecting to balanced devices use both + and – terminals. But if you are
connecting the output to unbalanced sinks (such as using 3.5mm mini-stereo
plugs),
do not
connect the unused outputs to ground. You can connect the
tip and ring to either + sides or the – sides, as shown below.
Figure 4 –
Connecting balanced audio outputs to
unbalanced devices
If the matrix needs to be controlled via RS-232, plug the controller (or PC) to
the DB9 Female port on the rear of the matrix. Connection to PC’s DB9 Male
is made using a straight through DB9 Male-to-Female cable (as shown
below).
DB9-Female on Matrix
Controller DB9-Male
Pin Function
Pin Function
2
TX (output)
2
RX (input)
3
RX (input)
3
TX (output)
5
Ground
5
Ground
Table 2 – RS-232 Control Port Pinout
Note on RS-232 port availability on PC
Most PCs do not have a serial port, so you may need
a USB to RS-232 Serial converter. These are available
from Hall Research (Model USB-RS232-1).
The 4x4 VSM matrix is available with IP port (VSM-I- …). On these units
there is an RJ45 (10/100 Base-T) for connection to your Local Area Network.