beautypg.com

4 special commands, 5 error responses – Hall Research VSM-I-A-4-JA4 User Manual

Page 16

background image

User’s Manual

14

4.4 Special Commands

Command:

FD«

Stands for Recall Factory Defaults

Response:

FD«

Command:

FW«

Stands for Firmware Version

Response:

FWx.y«

Command:

ST«

Stands for Status request

Response:

PW1«

CV1,m« CV2,m« CV3,m« CV4,m«

CA1,m« CA2,m« CA3,m« CA4,m«

4.5 Error Responses

ERR1«

Command is not recognized, has invalid parameter or wrong syntax

ERR2«

The only valid command while power is off is Power Status query (PW«), all

other commands issued while power is off will result in this error message

Notice

Factory Default command will clear all audio/video ties and

presets. The units with IP interface have a slightly different

response to this command. Please see section 5.3 for further details

Notice

The 4x4 VSM matrices equipped with IP Port have additional Serial

Commands to change IP address parameters. Please refer section

5.3 IP Specific Serial Commands for further info

This manual is related to the following products: