2 preset save and recall functions, 3 power functions, 4 special commands – Hall Research HSM-I-04-04 User Manual
Page 14: User’s manual 12
![background image](/manuals/737072/14/background.png)
User’s Manual
12
Command:
COn,m
Response:
COn,m
Variations:
Command:
COn
Response:
COn,m
Command:
CO*,m
Response:
CO1,m
CO2,m
CO3,m
CO4,m
4.2 Preset Save and Recall Functions
Command:
PRx
Response:
CO1, m
1
CO2, m
2
CO3, m
3
CO4, m
4
Command:
PSx
Response:
None (the current tie pattern is saved in EEPROM)
4.3 Power Functions
Command:
PW1
Response:
PW1
CO1, m
1
CO2, m
2
CO3, m
3
CO4, m
4
Important Note on Power ON Command
This command can take up to 10 seconds to complete. Upon powering up the unit will recall
the previous state of each output prior to powering off and restore each connection.
Command:
PW0
Response:
PW0
Variation:
Command:
PW
Response:
PWx
4.4 Special Commands
Command:
FB
Response:
Depends on power state when the command was issued. This command is
equivalent to unplugging the power supply and reconnecting it.