Symptom

Problem

Corrective Action

1.

Temperature setting is
too low

1.

Turn up the thermostat

2. Dirty

filter

2. Clean

filter

Does not heat

3. Flow

switch

malfunction 3.

Call for service

1.

Temperature setting is to
high

1.

Turn down the thermostat

Too hot

2.

High limit tripped

2.

Call for service

Erroneous
temperature of
0
° C (32°F)or
57.8
° C (136°F)
appears on the
display

Possible temperature sensor
failure

Call for service

Hot Tub
Temperature
erratic

Water level

Fill with water to the bottom of the OptiMount™ located next to the
Skimmer Basket.

1.

Too much filtration

1.

Reduce the number of filter cycles and/or the filter cycle duration

2.

Temperature setting too
high

2.

Turn down the thermostat

Display reads
OVERHEAT

3.

High limit or sensor
problem

3.

Call for service

Electrical System

Symptom

Problem

Corrective Action

Will not turn on
– in any mode

No power

Check circuit breaker and/or GFCI

Turns on by itself

Normal automatic daily
power filtration, or anti-
freeze cycle

No action required

Light is out

Burned out bulb

Replace bulb

1. Automatic

timer

has shut pump off

1.

Push JETS pad again to start another cycle

Pump shuts
down
unexpectedly
while in use

2. Motor

over-heated

and automatic
protective device
has shut down
pump(s)

2.

If pump(s) will not restart when JETS pad is pushed, call for service

Make sure that the equipment panel vent area is not blocked. Vent blockage
can cause serious damage to your equipment.