Hall Research UHBX-SW3-WP User Manual
Page 8
Software Guide
6
© Copyright 2015. Hall Research, Inc.
All rights reserved.
certain and verified that you have such information. Furthermore, even if that information
is available, if separate On and Off IR commands are not provided, it is possible to get
the system out of sync with the display. Therefore, it is highly advised to use RS232
whenever possible. Also remember that the wall plate does provide an IR detector and
for simple installations, the user can just point the remote to the wall plate and extend it
to the display.
A command can be up to 40 bytes long, and it can be a combination of serial, IR, and
delay commands.
Function – It is used to select an on or off command to configure.
Protocol – It consists of serial and IR to use for a protocol.
Serial Commands
A serial command can send data to any standard serial device with selectable baud
rate and parity.
Hexadecimal characters may be entered by using &h in front of the 2 digit
hexadecimal character (e.g. &hbe&hef&h00&h00&h01).
Commands are entered in the command text box. When done, you can click the
Add button to append the command as shown in the figure above.
IR Codes
As cautioned above . IR can only be used if the exact protocol of the IR (such as RC5,
NEC, etc) and the address and data bytes for the button are known.
Supported IR formats are: NEC, JVC, RCA, RC5, Sony, and Extended NEC.
Select the desired IR protocol and enter address along with command. When done,
just click the Add button to append the command.