14 replacement of parts – Glow-worm EnergySaver 80 User Manual
Page 38
38
221837B
Diagram 14.13
Diagram 14.12
Diagram 14.14
VIEWING WINDOW/INNER CASE
GASKET
VIEWING WINDOW/COMBUSTION
CHAMBER FRONT PANEL
14 Replacement of Parts
SIDE INSULATION
4382 S
5549
4076 S
FRAME
SECURING
SCREW (2)
GLASS
FRAME
SECURING
SCREW (2)
GLASS
GASKET
CONDENSATE
SENSOR
SCREW
14.14 Insulation - Sides - diagram 14.12
Remove the spark electrode refer to Section 12.4.
Remove the insulation by sliding it out.
14.15 Condensate Sensor: diagram 14.13
Refer to the relevant parts of Section 14.2 to remove the screw.
The sensing screwis fitted to a push fit cap which can be levered
off for easy access.
Note. The condensate flexible tube is a push fit and can be
removed from the condensate drain trap to improve access to
screw.
When replacing the cap make sure that the ring tag is pointing
away from th casing side.
14.16 Viewing Window Glass: diagram 14.14
Remove the two screws to release the frame and glass.
When replacing take care not to damage the gasket.
14.17 Inner Case Cover Seal
When removing seal make sure that all the old adhesive is
removed.
When fitting the new seal make sure that it fits correctly and has
not buckled.
14.18 Fascia and Lights Assembly
Release the control box as Section 9.
Refer to the relevant parts of Section 14.5 to remove the fascia
and lights bracket.