7 Flue Installation
7.4 External Flue Installation
Locate the air duct/terminal assembly into the flue elbow
assembly as shown in diagram 7.5, making sure of correct
terminal alignment of the “TOP”.
Mark the position of the air duct terminal assembly securing
holes and drill two 2.8mm diameter holes through the air duct/
terminal assembly.
Apply sealant to the flue duct and locate into air duct terminal,
see diagram 7.8.
From outside, place the air duct/terminal assembly and flue
duct into the flue hole.
Make sure that the flue terminal is correctly positioned and
projecting the correct distance from the outside wall face, see
diagram 7.11.
Apply sealant to the flue elbow spigot and then locate the flue
and air duct terminal assembly as shown in diagram 7.5, make
sure of the correct alignment of the “Top”.
Secure the air duct terminal to the flue elbow with the two self
tapping screws supplied in the loose items pack, then seal with
the tape provided.