beautypg.com

4 flue, 1 terminal position, 2 terminal guard – Glow-worm EnergySaver 80 User Manual

Page 13: 3 flue collar kit

background image

13

221837B

Diagram 4.4

4 Flue

A

A

F

G

E

A

G

G

G

B,C

B,C

F

F

K

K

K

C

G

L

L

A

DIRECTLY BELOW AN OPENABLE
WINDOW, AIR VENT, OR ANY OTHER
VENTILATION OPENING

300

B

BELOW GUTTER, DRAIN/SOIL PIPE

75

C

BELOW EAVES

200

E

FROM VERTICAL DRAIN PIPES AND
SOIL PIPES

75

F

FROM INTERNAL OR EXTERNAL
CORNERS

300

G

ABOVE ADJACENT GROUND OR
BALCONY LEVEL

300

H

FROM A SURFACE FACING THE
TERMINAL

600

*

I

FACING TERMINALS

1200

K

VERTICAL FROM A TERMINAL

1500

L

HORIZONTALLY FROM A TERMINAL

300

MINIMUM SITING DIMENSIONS
FOR FANNED FLUE
TERMINALS POSITION

MINIMUM

SPACING

in mm

H,I

0103 M

4.1 Terminal Position

The minimum acceptable spacings from the terminal to
obstructions and ventilation openings are as shown in diagram
4.4.

The boiler must be installed so that the terminal is exposed to
the external air.

It is important that the position of the terminal allows the free
passage of air across it at all times.

Note: The flue will produce a plume of condensation in cold
weather, so special care must be taken in the siting of the flue
terminal so as not to cause a nuisance to adjacent property.

Where the terminal is fitted within 600mm (24in) below plastic
guttering an aluminium shield 1500mm (5ft) long should be
fitted to the underside and immediately beneath the guttering or
eaves.

Where the terminal is fitted within 450mm (18in) below eaves or
painted guttering an aluminium shield 750mm (2ft6in) long
should be fitted to the underside and immediately beneath the
guttering or eaves.

4.2 Terminal Guard

A terminal guard is required if persons could come into contact
with the terminal or the terminal could be subject to damage.

If a terminal guard is required, it must be positioned to provide
a minimum of 50mm clearance from any part of the terminal and
be central over the terminal, see diagram 4.4.

A suitable terminal guard can be obtained from:

Tower Flue Components Ltd.,
Morley Road,
Tonbridge,
Kent
TN9 1RA

their reference CGD K3 BL

4.3 Flue Collar Kit

A flue collar kit, part No. 443286 (with instructions) is available.

Please note, the use of this collar will mean that the flue lengths
will need to be altered, full instructions are given in the kit.

0161M

* It may be necessary to increase this dimension to prevent
staining of adjacent walls depending on weather conditions.