221837B

2 Water Sytem

Diagram 2.5

METHOD 1

METHOD 2

METHOD 3

SUPPLY STOP
VALVE

SUPPLY
PIPE

HOSE
UNIONS

SERVICING
VALVE

TEMPORARY
HOSE

HEATING
SYSTEM

HEATING
SYSTEM

TEMPORARY
HOSE

HOSE
UNIONS

SERVICING
VALVE

SUPPLY
PIPE

SUPPLY STOP
VALVE

DOUBLE CHECK
VALVE ASSEMBLY

HEATING
SYSTEM

SERVICING
VALVE

SUPPLY
STOP VALVE

SUPPLY
PIPE

HOSE
UNIONS

DOUBLE CHECK
VALVE ASSEMBLY

OVERFLOW

CISTERN

COMBINED
CHECK VALVE
AND VACUUM
BREAKER

PRESSURE
REDUCING
VALVE

0051M

2.11 Expansion Vessel

A diaphragm type expansion vessel, conforming to the current
issue of BS4814 (see also BS7074 Part 1 and 2) must be
connected at a point close to the inlet side of the circulating
pump, see the diagrammatic layout, diagram 2.4 unless laid
down differently by the manufacturer.

The expansion vessel volume depends on the total water
system volume and the initial system design pressure. For any
system an accurate calculation of vessel size is given in the
current issue of BS7074 Part 1.

Example: For an initial system design pressure of 0.7bar, the
minimum total vessel volume required is 0.063xTotal System
volume.

Note: A higher initial design pressure requires a larger volume
expansion vessel.

Guidance on vessel sizing is also given in the current issue of
BS5449 and BS7074 Part 1.

The charge pressure must not be less than the static head of the
system, that is, the height of the highest point of the system
above the expansion vessel.

The water content of the boiler is given in the Data Table 1.

2.12 Pressure Gauge

A pressure gauge with a set pointer and covering at least 0 to
4bar (0 to 60lb/in

2

) shall be fitted permanently to the system in

a position where it can be seen when filling the system.

2.13 Domestic Hot Water Cylinder

SINGLE FEED INDIRECT CYLINDERS ARE NOT SUITABLE.

The hot water cylinder must be of the indirect coil type. It must
be suitable for working at a gauge pressure of 0.35bar above
the safety valve setting.

2.14 Water Makeup

Provision should be made for replacing water loss from the
system using a make up bottle or filling loop mounted in a
position higher than the top point of the system, connected
through a non-return valve to the return side of either the
heating circuit or the hot water cylinder.

Alternatively, provision for make up can be made using a filling
loop.

2.15 Filling a Sealed Water System

Provision for filling the system at low level must be made. Three
methods are shown in diagram 2.5. There must be no permanent
connection to the mains water supply, even through a non-
return valve.