beautypg.com

Remote control setting: sw1&sw2 – FeiYu Tech FY-41AP User Manual

Page 14

background image

Guilin Feiyu Electronic Technology Co., Ltd.

Guilin Feiyu Electronic Technology Co., Ltd http://www.feiyudz.cn [email protected]

Page 14



Remote control setting: SW1&SW2

 FY-41AP needs remote control and receiver with at least 6 channels, including 4

normal channels for AIL,ELE,THR,RUD, and two for SW1,SW2 to control flying
mode.

 You need to choose normal fixed wing plane mode canceling all mix control modes,

meanwhile setting CH5,CH6 to two three-switch.

 FY-41AP need two three-switch to control flying mode:SW1 for deactivated mode,

stable mode, 3D mode; SW2 for return to home and path flight (default
mode),circle, and fixed attitude and head locking mode(need set)

 After setting the Switch, you can double check by monitoring the indicator light on

the module against selected flying mode. Detail see the indicator light manual

 SW1&SW2 default set:

SW1

SW2

deactivated

Path flight

stable

NULL

3D

Path flight

NOTE: SW-2 has priority over SW-1. Only when SW-2 is in the ‗Null‘ Mode can

SW-1 work. Therefore ‗Null‘ should be one of the options for SW-2, otherwise SW-1

will not work.