1.0 Introduction

The

ISA-60M

W

/MRI-5175

is an ambient air monitoring system that measures oxygen concentrations in magnetic resonance

imaging environments. The

ISA-60M

control panel is capable of monitoring from 1 to 3

MRI-5175

remote sensors. Note: The

ISA-60M

and

MRI-5175

are produced as an aligned set and should be installed as such. Some features of the monitoring

system are as follows:

continuous monitoring of the sample air

continuous

LCD

display oxygen concentrations, at

ISA-60M

menu driven operational and maintenance controls

menu driven calibration procedure

audio and visual alarms indicate unsafe conditions

alarm relay contacts available on terminals

a fault relay and visual fault alarm

alarm acknowledgement capability including audio defeat,

ISA-60M

control only

mA output for each channel

internal non-magnetic metallic coating of MRI-5175 to minimize RFI/EMI

N

OTE

:

All specifications stated in this manual may change without notice.

1.1 IEC 60601-1 Classifications

Type of protection against electrical shock: Class 1.

Degree of protection against electrical shock: No Applied Parts

- Equipment not suitable for use in presence of flammable anesthetic mixture with air or with oxygen or nitrous oxide.
- Mains power quality should be that of a typical commercial or hospital environment.
- Power frequency magnetic fields should be at levels characteristic of a typical location in a commercial or hospital

environment.

1.2 Unpack

Unpack the

ISA-60M

and examine it for shipping damage. If such damage is observed, notify both

ENMET

customer service personnel and

the commercial carrier involved immediately.

Regarding Damaged Shipments

N

OTE

:

It is your responsibility to follow these instructions. If they are not followed, the carrier will not honor any

claims for damage.

This shipment was carefully inspected, verified and properly packaged at our company and delivered to the carrier in good condition.

When it was picked up by the carrier at

ENMET

, it legally became your company’s property.

If your shipment arrives damaged:

Keep the items, packing material, and carton “As Is.” Within 5 days of receipt, notify the carrier’s local office and request
immediate inspection of the carton and the contents.

After the inspection and after you have received written acknowledgment of the damage from the carrier, contact

ENMET

Customer Service for return authorization and further instructions. Have your Purchase Order and Sales Order numbers available.

ENMET

either repairs or replaces damaged equipment and invoices the carrier to the extent of the liability coverage, usually $100.00.

Repair or replacement charges above that value are your company’s responsibility.

The shipping company may offer optional insurance coverage.

ENMET

only insures shipments with the shipping company when

asked to do so in writing by our customer. If you need your shipments insured, please forward a written request to

ENMET

Customer

Service.

Regarding Shortages

If there are any shortages or questions regarding this shipment, please notify

ENMET

Customer Service within 5 days of receipt at the

following address:

ENMET Corporation

680 Fairfield Court

Ann Arbor, MI 48108

734-761-1270

734-761-3220 Fax

1.3 Check Order

Check, the contents of the shipment against the purchase order. Verify that the

ISA-60M

is received as ordered. If there are accessories on

the order, ascertain that they are present. Check the contents of calibration kits. Notify

ENMET

customer service personnel of any

discrepancy immediately.

1.4 Serial Numbers

Each

ISA-60M

and

MRI-5175

is serialized. These numbers are on tags on the equipment and are on record in an

ENMET

database.