410sx operator’s manual – Ditch Witch 410SX User Manual
Page 28

410sx Operator’s Manual
Controls - 27
Tractor
CMW
2.
Operator presence
switch
Detects when operator is
present.
Press and hold switch before
moving ground drive control
or digging controls out of
neutral.
If switch is released during operation,
alram will sound and engine will die.
3.
Hydraulic fluid
temperature indicator
Lights if hydraulic fluid
overheats.
If light remains on:
•
Check that engine fan is turning
when engine is running.
•
Turn off engine and let it cool.
•
Check hydraulic fluid level.
•
Check front of hydraulic cooler for
debris.
4.
Check engine /
Malfunction indicator
light
Lights when an engine
problem has been detected.
Lights momentarily when ignition
switch is turned to the ON or START
position.
5.
Engine information
display
Displays status of certain
engine functions: RPM,
engine hours, battery voltage,
oil pressure, coolant
temperature, and engine
diagnostic codes.
See “Engine Diagnostic Codes” on
page 78.
“Engine hours” refers to amount of
time key is on position without engine
running. “Machine Hours” refers to
amount of time engine has been
running above 100 rpm.
Item
Description
Notes
c00ic039w.eps
!