beautypg.com

Debris tank, Fx20 operator’s manual – Ditch Witch FX20 User Manual

Page 81

background image

Service - 80

FX20 Operator’s Manual

As Needed

CMW

Debris Tank

Clean Primary Shutoff Valve

Clean primary shutoff valve as needed. Replace primary shutoff valve as needed.

To clean:

1.

Open tank door. See “Drain Tank” on page 48.

2.

Spray valve housing inside vacuum tank with high-pressure water.

3.

Store water pressure hose.

4.

Close tank door. See “Drain Tank” on page 48.

To remove:

1.

Disconnect hose from elbow.

2.

Remove bolts (1) and pull out valve housing
(2).

3.

Remove ball (3).

4.

Clean ball and housing with high-pressure
water.

5.

Replace ball and housing.

6.

Tighten nuts.