Page 79
Service - 78
FX20 Operator’s Manual
As Needed
CMW
Change Water Pump Filter
1.
Open filter housing.
2.
Remove element and rinse housing
thoroughly with water.
3.
Replace element.
4.
Close filter housing.
Adjust Water Pump Belt Tension
1.
Turn off engine and remove key.
2.
Apply moderate thumb pressure to belt
between pulleys. Belt is properly tensioned
when deflection is about 1/4” (5-8 mm).
3.
If needed, loosen four bolts (1).
4.
Turn adjustment screw (2) clockwise or
counterclockwise until tube touches bracket.
5.
Tighten four bolts.
NOTICE: Be sure filter element is
properly seated.
See also other documents in the category Ditch Witch Special machinery:
- JT5 (161 pages)
- JT922 (159 pages)
- JT9 (165 pages)
- JT20 (195 pages)
- JT1220 (201 pages)
- JT2020 (203 pages)
- JT25 (203 pages)
- JT30 (245 pages)
- JT60 (218 pages)
- JT100 (243 pages)
- AT Air Hammer (11 pages)
- TK Series Manual (61 pages)
- 8500 (77 pages)
- MR90 (121 pages)
- FT5 (28 pages)
- FM5 (57 pages)
- FM13V (46 pages)
- FM25 (67 pages)
- P80 (71 pages)
- OnGrade (63 pages)
- FX25 (119 pages)
- FX30 (149 pages)
- FX50 (141 pages)
- FX60 (157 pages)
- MV800 (111 pages)
- RT Line (115 pages)
- RT30 (97 pages)
- RT45 (203 pages)
- RT55 (177 pages)
- RT100 (161 pages)
- RT115 (252 pages)
- RT120 (223 pages)
- Zahn (105 pages)
- RT80 (203 pages)
- RT115 Q (193 pages)
- RT120 Q (211 pages)
- 100SX (50 pages)
- 410SX (131 pages)
- SK350 (77 pages)
- SK750/SK755 (81 pages)
- SK850 (107 pages)
- SK850 Footings Machine (107 pages)
- 150RT (55 pages)
- 250RT (49 pages)