beautypg.com

50 hour, Vacuum system, Fx20 operator’s manual – Ditch Witch FX20 User Manual

Page 67

background image

Service - 66

FX20 Operator’s Manual

50 Hour

CMW

50 Hour

Vacuum System

Check Water Pump Belt Tension

Check belt every 50 hours for correct tension,
damage or wear. Replace worn belt. Tighten as
needed. See “Adjust Water Pump Belt Tension”
on page 78.

To check

1.

Turn ignition to STOP and remove key.

2.

Apply moderate thumb pressure to belt
between pulleys.

3.

Belt is properly tensioned when deflection is
about 1/4” (5-8 mm).

Location

Task

Notes

Vacuum
System

Check water pump belt tension

Check blower belt tension

Check blower relief valve

Lube blower bearings

MPG

Check water pressure hoses

Check vacuum air filter and hoses

Debris Tank

Lube door handle screw