beautypg.com

As needed, Vacuum system, Fx20 operator’s manual – Ditch Witch FX20 User Manual

Page 78

background image

FX20 Operator’s Manual

Service - 77

As Needed

CMW

As Needed

Vacuum System

Adjust Blower Belt Tension

1.

Turn off engine.

2.

Loosen 4 bolts (2) from underneath skid.

3.

Loosen u-bolt (4) to allow blower to slide.

4.

Insert prybar in hole (3) and move blower
until belt is tight.

5.

Apply moderate thumb pressure to belt
between pulleys. Belt is properly tensioned
when deflection is about 1/4” (5-8 mm).

6.

Tighten 4 bolts and u-bolt.

7.

Verify tensioner (1) is set with the fixed bar
3.5 lines from the bottom of the scale on the
tensioner arm.

Location

Task

Notes

Vacuum
System

Adjust water pump belt tension

Change water pump filter

Adjust blower belt tension

Lube blower for longterm storage

Change blower relief air filter

Debris Tank

Clean primary shutoff valve

NOTICE: Over-tightening blower drive belts may result in premature blower shaft or engine bearing