Refer ence man ual, Wir eless fuzzyscan – Cino PL680BT HC User Manual
Page 88
![background image](/manuals/734553/88/background.png)
W
ir
eless FuzzyScan
R
efer
ence Man
ual
Configure Your FuzzyScan
80
PROGRAM
Operation Control
(All Series)
♦ Out-of-range Scanning, Link Supervision Time-out ♦
F_DEFAULT
Family Code Selection
P.C
Parameter Selection
Option Code
Out-of-range Scanning
SS
SS
Disable
Enable
0
1
Link Supervision Time-out
SS
SS
SS
SS
SS
1 sec
3 secs
5 secs
7 secs
9 secs
Only available in PAIR & PICO modes
0
1
2
3
4
Out-of-range Scanning When radio link is built between the scanner and remote host device, the scanner will transmit each scanned data right after scanning the barcode
data. However, the scanner is preset for unable to scan any barcode data when it loses the radio connection. You can enable the Out-of-range Scanning function to
continue scanning barcode data into memory buffer until radio link resumed.
The Link Supervision Time-out is a pre-defined radio link supervision timeout setting. The scanner will supervise the radio link status every preset seconds.
.