Refer ence man ual, Wir eless fuzzyscan, Symbology reading control – Cino PL680BT HC User Manual
Page 49

W
ir
eless FuzzyScan
R
efer
ence Man
ual
Configure Your FuzzyScan
41
PROGRAM
Symbology Reading Control
♦ Code 128 Setting ♦
F_DEFAULT
Family Code Selection
P.C
Parameter Selection
Option Code
Code 128 Setting
SS
SS
SS
SS
Disable Code 128 and GS1-128
Enable Code 128 and GS1-128
ISBT Concatenation Off
ISBT Concatenation On
0
1
2
3
Code 128 Min. Length
SS
MS
Default (01)
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
FIN
(2 digits)
Code 128 Max. Length
SS
MS
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
FIN
(2 digits)
Code 128 Security Level
SS
SS
Level 0
Level 1
0
1
Code 128 Security Level
The scanner offers two levels of decode security for Code128 bar codes:
Level 0: If you are experiencing misread of poor-printed or out-of-spec. bar code in level1, please select level 0.
Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding "in-spec." Code128 bar codes.