Refer ence man ual, Wir eless fuzzyscan – Cino PL680BT HC User Manual
Page 84
![background image](/manuals/734553/84/background.png)
W
ir
eless FuzzyScan
R
efer
ence Man
ual
Configure Your FuzzyScan
76
PROGRAM
Operation Control
(F, L, PF & PL Series)
♦ Scan Rate Control, ♦
F_DEFAULT
Family Code Selection
P.C
Parameter Selection
Option Code
Scan Rate Control
SS
SS
Dynamic
Fixed
0
1
Scan Rate Control: The scanner will have better motion tolerance when you select “Fixed” scan rate. It’s suitable for application which needs higher motion tolerance on
the move. But this may impact to the reading distance.