OPTIONAL 12 VOLT BATTERY BACK-UP


WARNING: ALWAYS DISCONNECT POWER CORD DURING ANY ELECTRICAL OPERATION
Note: Never use an unsealed battery

1.

Disconnect the 110 volt AC power before connecting the 12 volt battery.

2.

Determine the location for the 12 volt battery and obtain the proper length and type of wire (Use 18 gauge
stranded wire)

3.

Drill and install 1/2” conduit where passing through a wall or floor.

4.

Connect a red 18 gauge wire to red positive (+) battery terminal on the stove.

5.

Install a 4 amp inline fuse on the red positive wire near the stove.

6.

Connect a black 18 gauge wire to black negative (-) battery terminal on the stove.

7.

Pass wire through the conduit to battery location. Allow enough wire length between battery box and exterior
wall for a drip loop to prevent moisture from reaching terminals. (see diagram)

8.

Connect the red positive (+) lead to the positive (+) battery terminal.

9.

Connect the black negative (-) lead to the negative (-) battery terminal.

10.

Reconnect the 110 volt AC power. The stove is now ready for 12 volt back-up and will switch automatically to
12 volt operation when AC power is lost. When AC power is restored, the stove will automatically switch back
to AC power and recharge the battery.
NOTE: THE SELF IGNITER WILL NOT START THE STOVE IN THE DC POWER MODE. (12v
Battery Back-up)


STARTING THE STOVE IN DC POWER MODE (12v Battery Back-up)

1.

Clean out and dump the firepot.

2.

Pull the air damper rod out to approximately ¼ to ¾.

3.

Turn the “Fuel Feed Control” to the 3

rd

position.

4.

Open the door and add approved fire starter to ½” of pellets in the firepot and light the fire starter. Once the fire
starter is burning freely, close the door.

5.

When the pellets are burning well, press the “On/Off” switch to the “On” position.

6.

Let the fire continue to build approximately 1 minute, then push the “Start” button.

DRIP LOOP

4 AMP FUSE ON
POSITIVE LEAD

ELECTRICAL CONDUIT

WHERE PASSING

THROUGH A WALL

VENTED

BATTERY

BOX

12 V

+ DENOTES POSITIVE

- DENOTES NEGATIVE

P

N EG.

S.

O

FRESH AIR

BATTERY

CONNECTIONS

POWER
CORD