8 power, 9 mechanical and environmental, 10 operating systems support – ADLINK ETX-BT User Manual
Page 12: Operating systems support

Page 12
2.8 Power
X
Standard Input: ATX = 5V±5% / 5Vsb ±5% or AT = 5V±5%
X
Management: ACPI 4.0 compliant, Smart Battery support
X
Power States: C0, C1, C1E, C4, C6; S0, S3, S4, S5 (Wake on USB S3/S4,WOL S3/S4/S5)
X
ECO mode: supports deep S5 (ECO mode) for power saving
2.9 Mechanical and Environmental
X
Form Factor : ETX Rev 3.02
X
Dimension: 114 mm x 95 mm
X
Standard Operating Temperature: 0°C to +60°C
X
Screened Extreme Rugged™ Operating Temperature: -40°C to +85°C (optional)
X
Humidity: 5-90% RH operating, non-condensing
5-95% RH storage (operating with conformal coating)
X
Shock and Vibration:
IEC 60068-2-64 and IEC-60068-2-27
MIL-STD-202F,
Method
213B, Table 213-I, Condition A and
Method 214A, Table 214-I, Condition D
X
HALT Tested: Thermal Stress, Vibration Stress, Thermal Shock and Combined Test
X
MTBF: MIL-HDBK-217 FN2 models; Environment: GB, GC - Ground Benign, Controlled
Temperature:
85°C:
MTBF=79,548
hrs
Temperature: 40°C : MTBF=278,025 hrs
2.10 Operating Systems Support
X
Standard OS Support: Windows 7 & 8.1 32/64-bit, Linux 32/64-bit
X
Extended Support (BSP): WES7/8 32-bit, WEC7/8, Linux, VxWorks, QNX