beautypg.com

ADLINK ASD8P-MT1 Series User Manual

Page 15

background image

ASD8P-MT1 Specification

Page 15 of 43

Test

Description

Performance

criteria

Reference

standard

Radiated RF immunity

80~1000MHz, 3V/m,

80% AM with 1 KHz

sine

900 MHz, 3 V/m, 50%

pulse modulation at

200Hz

A

IEC 61000-4-3:

2008

Electrical fast transient

±1KV on AC mains ±0.

5KV on external I/O

B

IEC 61000-4-4:

2004

+Corr. 1: 2006
+Corr. 2: 2007

Surge immunity

±1KV differential ±2KV

common, AC mains

B

IEC 61000-4-5:

2005

Conducted RF immunity

150KHz~80 MHz, 3
Vrms, 80% AM with

1KHz sine

A

IEC 61000-4-6:

2008

Power frequency

magnetic field

50Hz, 1A/m (r. m. s. )

A

IEC 61000-4-6:

2008

Notes:

1) Performance criterion A = The device shall continue to operate as intended, i. e. ,

normal unit operation with no degradation of performance.

2) Performance criterion B = The device shall continue to operate as intended after

completion of test, however, during the test, some degradation of performance is

allowed as long as there is no data loss operator intervention to restore device function.

3) Performance criterion C = Temporary loss of function is allowed. Operator

intervention is acceptable to restore device function.

4) Contact electrostatic discharge is applied to drive enclosure.


Weight

13g Max. (LGT-xxxB1P)


Dimension

Form factor M. 2 2280: 80. 0 mm x 22. 0 mm x 3. 8 mm (L x W x H) (LGT-xxxB1P)