Problem

Ensure that:

System fails to
power up

X

The power cord is securely

plugged into the chassis power
connector and wall socket/power
strip

X

The wall socket/power strip is live

X

The main power switch on the

back of the chassis is turned on

X

The standby power button on the

chassis front panel is turned on

No video output in
the external display

X

The external display is function-

ing properly

X

Display settings support external
video.

Power LED (blue) is
blinking

X

There is no short circuit by

removing all PXI modules (PXI
controller and peripheral mod-
ules)

If the signal persists, contact your dealer for further
assistance

Fan LED (green) is
blinking

X

The fan is unobstructed

If the signal persists, contact your dealer for further
assistance.

Temperature LED
(amber) is blinking

X

Airflow from the outlet apertures

is unobstructed and steady; if not,
ensure that adequate clearance
for the intake apertures is pro-
vided

If the temperature of exhausted air is normal (below
50°C) but the temperature LED is still blinking,