beautypg.com

ADLINK PXES-2590 User Manual

Page 62

background image

52

Monitoring/Control

Functions

Data format is as follows:

*Write 5Vsb Alarm Threshold (command 0xBA)

Writes the 5Vsb Alarm Threshold.

Use the SMB write word to write this word data

Data format is as follows:

*Write Fan Speed Alarm Threshold (command 0xBC)

Writes the Fan Speed Alarm Threshold.

Bit

Description

7..0

-12V Under Voltage Alarm Threshold. Unsigned 8-bit
data, the LSB is 0.1%. If the -12V voltage is lower than
this threshold, the MCU triggers a voltage alarm. The
threshold range is between 0 and 250

15..8

-12V Over Voltage Alarm Threshold. Unsigned 8-bit data,
the LSB is 0.1%. If the -12V voltage is higher than this
threshold, the MCU triggers a voltage alarm. The
threshold range is between 0 and 250

SMB

Dir

Offset

Value

Description

Write word

>

0

SA

Slave address

>

1

0xBA

Command code

>

2

0-255

Low byte data

>

3

0-255

High byte data

Bit

Description

7..0

5Vsb Under Voltage Alarm Threshold. Unsigned 8-bit
data, the LSB is 0.1%. If the 5V standby voltage is
lower than this threshold, the MCU triggers a voltage
alarm. The threshold range is between 0 and 250

15..8

5Vsb Over Voltage Alarm Threshold. Unsigned 8-bit
data, the LSB is 0.1%. If the 5V standby voltage is
higher than this threshold, the MCU triggers a voltage
alarm. The threshold range is between 0 and 250