beautypg.com

ADLINK PXES-2590 User Manual

Page 55

background image

Monitoring/Control Functions

45

PXES-2590

Data format is as follows:

*Block Read Chassis Data Part 1 (command 0x46)

Block reads the Chassis Data Structure Part 1.

Use the SMB Block Read to Read this data structure.

Data Format Description:

The entire Chassis Data Structure is as:

typedef struct st_BlockRead

{
INT16 P_5V;
INT16 P_3V3;
INT16 P_5Vsb;
INT16 P_12V;
INT16 P_N12V;
INT16 T1;
INT16 T2;
INT16 T3;
INT16 T4;

Bit

Description

15..0

Fan Speed Mode:
0: Auto
1: Full Speed
2: Low Speed

NOTE:

NOTE:

Use command 0x46 first, then command 0x47 to acquire the
entire data structure.

SMB

Dir

Offset

Value

Description

Block Read

>

0

SA

Slave address

>

1

0x46

Command code

>

2

SA

Slave address

>

3

26

Byte count

>

4~31

0-255

Data Structure upper part