38

Monitoring/Control

Functions

*Read 5Vsb Voltage ( command 0x0C)

Reads the 5Vsb Voltage

Use the SMB 1 Send Byte and 2 Receive Byte to Read this
word data:

Data format is as follows:

*Read Temperature 1 (command 0x10)

Reads the Temperature 1 Reading.

Use the SMB 1 Send Byte and 2 Receive Byte to Read this
word data.:

SMB

Dir

Offset

Value

Description

Send Byte

>

0

SA

Slave address

>

1

0x0C

command code

Receive Byte

>

2

SA

Slave address

<

3

0-255

Low byte data

Receive Byte

>

4

SA

Slave address

<

5

0-255

High byte data

Bit

Description

15..0

5Vsb Voltage. Measured 5V standby voltage. 16-bit
2’s complement, the LSB is 1mV

SMB

Dir

Offset

Value

Description

Send Byte

>

0

SA

Slave address

>

1

0x10

Command code

Receive Byte

>

2

SA

Slave address

<

3

0-255

Low byte data

Receive Byte

>

4

SA

Slave address

<

5

0-255

High byte data