3 chassis status, Chassis status – ADLINK PXES-2590 User Manual
Page 42

32
System
Management
Fan Speed
Auto/Full status of the PXES-2590 is shown here, Auto is dis-
played when the cooling fans are set to auto mode and Full
when the fans are set to run full speed. Selection of Auto or
Full values and clicking Set directly changes cooling fan mode.
Alarm Threshold
Active alarm threshold settings are shown, including DC volt-
age, temperature, and fan speeds. The updated threshold set-
ting can also be set here, by entering the desired value and
clicking Set Threshold Settings.
3.2.3
Chassis Status
DC Voltage
The monitored 5V AUX, 3.3V, 5V, 12V, and -12V power rail
readings are shown here. The status shows as normal when
the readings are within the threshold range, and abnormal
when the readings exceed the threshold range.
Chassis Temperature
Temperature sensors T1 to T5 located on the backplane from
left to right provide status, showing as normal when under the
threshold value (70
°
C in the figure), and abnormal when
exceeding the threshold value.
Fan Speed
Monitored readings of the three cooling fans appear here. Sta-
tus shows as normal when readings exceed threshold value
(800 RPM in the figure), and abnormal when the readings fall
below the threshold value.