beautypg.com

Canon IMAGEFORMULA DR-X10C User Manual

Page 48

background image

40

3.

Lift the pickup roller mounting lever, and remove the
roller.

4.

Pull the feed roller lock lever down (a) and move it to
the right (b) to unlock the feed roller.

5.

Remove the feed roller.

6.

Use a moistened, well wrung-out cloth to wipe off any
dust from the rollers.

Reinstalling Pickup and Feed Rollers
1.

Set the pickup roller (a) in place and push the
mounting lever (b) back to secure it.

2.

Align the notches in the shaft of the feed roller with
the pins on the shaft in the scanner, and place the
feed roller into position.