Cleaning the pickup and feed rollers, See “cleaning the pickup and, Feed rollers” on p. 39) – Canon IMAGEFORMULA DR-X10C User Manual
Page 47
39
3
Main
ten
a
nce
3.
Clean the black and white surfaces of the rollers by
wiping horizontally with a moistened, wrung-out
cloth.
IMPORTANT
When cleaning, be careful not to bend the sheet over the roller.
The location of the sheet for the lower platen roller is in front of
the roller.
4.
Use a soft object such as a cotton swab to remove
any dust adhering to the brushes, and any dust that
may have fallen from them.
IMPORTANT
Be careful not to bend the brush bristles when cleaning. If the
bristles are bent, their cleaning ability is degraded.
5.
Carefully lower the upper unit (a). Press down on
both sides of the upper unit to ensure that it is
securely closed. (b)
Cleaning the Pickup and Feed Rollers
Use the following procedure to remove and reinstall the
pickup and feed rollers during cleaning or replacement.
CAUTION
Do not use excessive force when removing or reinstalling the
rollers. Doing so may damage the rollers, resulting in feed errors.
■ Removing and Cleaning the Pickup and Feed
Rollers
1.
Carefully raise the upper unit until it stops.
2.
Lift the roller cover and pull out and downwards.
IMPORTANT
When opening and closing the roller cover, be careful not to
touch the glass (staple detection window). If the glass gets dirty,
staple detection accuracy is degraded.
Sheet (avoid bending)