WIRING DIAGRAMS
[ (1) IE-2AD(U) SYSTEM w/VIDEO MONITORING CAPABILITY;
The MFW-CZ camera (No. 3) must correspond each with video input terminals
I
3
I
(for coaxial cable) and
B3 (for video signal input) on MFW-P3.
Connect coaxial cable from MF-D thru MFW-P3 to terminal A on MFH-U.
In a system with more than one video monitor, remove impedance-matching plug on all video monitors,
except on the farthest monitor.
IE-2AD(U) can accept max. 2 video door stations, one each for lE-lAD(U) and lE-lGD(U).
Fold back braided conductors in a manner that core
conductor
be
not
bent
nor
shorted
to
braided
conductors.
¡COAXIAL CABLE CONNECTION;
II
COAXIAL
■ ■
COAXIAL
CABLE
—---------------- CABLE
a
I^^
b
5C-2V
RG-59/U (20GA)
11 mm (7/16")
3 mm (1 /8"
1
8.5 mm (5/16")
DO
NOT
REMOVE
THIS
GROUNDING
TERMINAL.
Connect
braided
conductors
with clamp.
MFH-U
-