beautypg.com

Wiring diagrams, 1) ie-2ad(u) system w/video monitoring capability – Aiphone MFH-U User Manual

Page 4

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

WIRING DIAGRAMS

[ (1) IE-2AD(U) SYSTEM w/VIDEO MONITORING CAPABILITY;

The MFW-CZ camera (No. 3) must correspond each with video input terminals

I

3

I

(for coaxial cable) and

B3 (for video signal input) on MFW-P3.

Connect coaxial cable from MF-D thru MFW-P3 to terminal A on MFH-U.

In a system with more than one video monitor, remove impedance-matching plug on all video monitors,

except on the farthest monitor.

IE-2AD(U) can accept max. 2 video door stations, one each for lE-lAD(U) and lE-lGD(U).

Fold back braided conductors in a manner that core

conductor

be

not

bent

nor

shorted

to

braided

conductors.

¡COAXIAL CABLE CONNECTION;

II

COAXIAL

■ ■

COAXIAL

CABLE

—---------------- CABLE

a

I^^

b

5C-2V

RG-59/U (20GA)

11 mm (7/16")

3 mm (1 /8"

1

8.5 mm (5/16")

DO

NOT

REMOVE

THIS

GROUNDING

TERMINAL.

Connect

braided

conductors

with clamp.

MFH-U

-

4