8.5.5 Replacing power cord
•
Remove 2 insulated faston receptacles (55) from mains switch (54).
•
If present, disconnect ground wire (15, part of thermoblock assembly).
•
Unlatch cable bracket (56) with screwdriver.
Use a pair of flat pli
ers to pull off insulat
ing sleeve with recep
tacle.
The counterpart, a
flat receptacle, has a
special connector
latching (see detail). Press
down lever at first, then pull
off receptacle.
The cable bracket is
under tension. There
fore, hold the cable
bracket with your finger
when unlatching it.