T R O U B L E S H O O T I N G
5 Measure coffee
temperature dur
ing preparation
(see page 136)
5.1 No coffee
YES a) water system is empty YES replace self priming
device (APD)
NO continue
YES b) flow meter blocked
YES clean or replace
NO continue
YES c) pyramide plate
blocked
YES replace the compact
brewing unit
NO continue
YES d) coffee machine is cal
cified
NO continue
YES descale coffee machine
(see page 41)
5.2 Temperature is too
low (below 83°C)
YES descale coffee machine
(see page 41)
NO continue
5.3 Temperature too
high (over 89 °C)
YES replace NTC tempera
ture sensor
NO continue
6 Check for leakage
(see page 133)
and measure flow
rate (see page
132)
6.1 Compact brewing
unit leaks
YES replace compact brew
ing unit
NO continue
6.2 Hose connections
leak
YES replace defective hoses
and seals
NO continue
6.3 Rate of flow not in
the standard range
YES coffee machine is calci
fied
NO continue with point 9
YES descale coffee machine
(see page 41)
NO replace pump
7 Descale coffee
machine
(if necessary)
7.1 Coffee machine is
calcified
YES descale coffee machine
(see page 41)
NO continue with point 9
8 Check water tank
contents after des
caling and rinising
8.1 Particles of calcium
and rust visible in
water
YES descale and rinse coffee
machine again to clean water
circuit (see page 41)
NO continue
YES inform customer to des
cale coffee machine periodi
cally and to use specified des
caling product only.
9 Final cleaning
(see page 38)
No errors found according to
check list?
YES for more information
please contact
Nespresso
Service Division
End of check list
Check
Error symptoms
Measure /
repair work
Further measures / repair
work