Nespresso Citiz & Co EF 488 User Manual
Page 106

Citiz service manual
106
R E P A I R S
Assembly checkpoints fine wire fuse(s)
•
When mounting a safety clip (a) on the thermoblock (15), make sure that the housing
of the fine wire fuse (b) is positioned exactly below the safety clip.
•
Tighten fastening screw and spring ring with a torque wrench (150 (+30/0) Ncm).
Assembly checkpoints thermoblock
•
All wires from thermoblock to platform must be led through the bracket (a) at the
bottom of the support.
•
The black grommets (b) on the electrical thermoblock connections are slitted at the
end. If an angled Faston receptacle (c) is used, make sure that its wire runs through
this slit.
•
Tighten central fastening screw (d) with a torque wrench (150 (+30/0) Ncm).