Nespresso Citiz & Co EF 488 User Manual
Page 65

Citiz service manual
65
R E P A I R S
•
Loosen 4 screws (41, oval shaped head) at the bottom side of platform.
For complete removal of the core unit proceed as follows:
•
Remove water tank connector (53) from platform (see page 59).
•
Remove insulated faston receptacle of phase wire (15) from mains switch (54).
•
Disconnect adapter plug (15) of neutral wire.
•
If present, disconnect ground wire (15, part of thermoblock assembly).
After this repair step
the core unit can be
pulled out of the plat
form slightly (with still con
nected hoses and wires).
Now the covers of the core
unit can be removed.
The hoses can
remain on the water
tank connector.
Use a pair of flat pliers
to pull off insulating
sleeve with recepta
cle.
The flat receptacle on
the ground wire has a
special connector
latching (see detail). Press
down lever at first, then pull
off receptacle.