Dealer assembly & pre-service, Battery set-up and maintenance – Ariens 935000 User Manual
Page 36
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
DEALER ASSEMBLY & PRE-SERVICE
BATTERY SET-UP
AND MAINTENANCE
A
WARNING:
STORAGE
BATTERIES
GIVE
OFF
HIGHLY
INFLAMMABLE
HYDROGEN
GAS.
DO
NOT
ALLOW
SPARKS OR FLAME NEAR BATTERY. DO NOT LAY
TOOLS
ACROSS
BATTERY
TERMINALS
WHICH
MAY
CAUSE A SPARK RESULTING IN AN EXPLOSION.
CAUTION:
ELECTROLYTE
CONTAINS
SULPHURIC
ACID
WHICH
IS
HARMFUL
TO
SKIN,
-EYES
AND
CLOTHING.
HANDLE
WITH
EXTREME
CARE.
IF
SPILLAGE OCCURS ON BODY OR CLOTHING, RINSE
AT ONCE WITH WATER.
WARNING:
REVERSED
BATTERY
CABLES
OR
REVERSED CABLES FROM A BATTERY CHARGER OR
BOOSTER
BATTERY
CAN
CAUSE
DAMAGE
TO
THE
PRODUCT.
SPARKS
AND
POTENTIAL
HAZARDS
TO
OPERATOR
COULD
RESULT.
MAKE
CERTAIN
THE
GROUND CABLE IS CONNECTED TO THE FRAME AND
THE
POSITIVE
CABLE
IS
CONNECTED
TO
THE
POSITIVE (+) TERMINAL.
NOTE: THE HYDROMETER, PART NO. 531 140, OF
FERED
THROUGH
ARIENS
IS
RECOMMENDED
FOR
ALL
SET-UP
AND
MAINTENANCE
PROCEDURES
OF
ARIENS BATTERIES.
SET-UP
Battery is dry charged. Dealer or customer must add
electrolyte (sulfuric acid and water).
1. Remove battery from unit.
2.
Remove all the vent caps from the battery and set
the caps to ope side.
3.
Take
the
electrolyte
which
should
be
1.265
Specific gravity at 80° F,* and fill each cell so that
the electrolyte is level with the bottom of the fill
ring.
4.
The battery should stand for
’/2
hour. Now check
electrolyte level in each cell again. If necessary
add more electrolyte to bring the level up to the
bottom of the fill ring.
5.
Charge until all cells are gassing freely, and the
specific gravity is constant over three successive
readings taken at 30 minute intervals. See Table 4
for charging rates.
6.
Immediately after charging check level of elec''
trolyte. If the level is low add distilled water to
bring it up to required level.
v
7. Replace vent caps. It is not necessary to tighten
more than finger tight.
8. Wash off the battery to remove electrolyte which
may have spilled.
PRODUCT
BATTERY
MODEL
CHARGE
RATE
FOR 10 HRS.
Yard Tractor
Ariens 291 75
(WISCO LM-9)
2.5 Amps
TABLE 4
NOTE: CHARGING BATTERY AT A HIGHER RATE WILL
DAMAGE BATTERY.
MAINTENANCE
If you wish to have the best performance possible, it is
extremely important to do periodic checks.
1.
Do an occasional visual inspection. See to it that
the battery remains clean' both the case and the
terminals. This visual inspection should be done
once a month.
2.
Check the level of the electrolyte. It may be
necessary to add distilled water. This should be
checked before each usage.
3.
Another important check is the specific gravity.
The specific gravity should be checked with the
Hydrometer*. The reading on the gauge should be
above 1.225. If the electrolyte is allowed to fall
below 1.225 specific gravity, you will have an in
sufficient charge. If this happens charge battery
until specific gravity of 1.265 is reached over 3
successive readings. This check should be done
monthly.
STORAGE
During the off season it is important to have the battery
in the same good condition or it will not deliver power
when needed.
1.
Make sure the battery is fully charged and the
electrolyte is to the proper level.
2.
Make sure the battery is clean (both the case and
the terminals.)
3.
After cleaning the terminals you may want t,
spread petroleum jelly on the terminals to prevent
loss of charge.
4.
Leave the cables disconnected.
3 6 -