Models 48n (sizes lt042300 thru ht042600) – Carrier 48N User Manual
Page 7
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Table 2—Specifications—Models 48N (Sizes NLT018300 thru NLT036600)
MODEL
48N
48N
48N
48N
48N
48N
48N
48N
48N
SIZE
LT018300
LT024300
HT024300
LT030300
MT030300
HT030300
LT036300
LT036500
LT036600
Unit Volts—Phase (60 Hz)
208/230—1 208/230—1 208/230—1 208/230—1 208/230—1 208/230—1 208/230—1 208/230—3
460—3
Operating Voltage Range
187—253
187—253
187—253
187—253
187—253
187—253
187—253
187—253
414—506
Unit Full Load Amps
11.5
14.2
14.2
16.8
16.8
17.3
21.2
14.6
7.7
Maximum Fuse Size (Amps)
20
25
25
30
30
30
40
25
15
Minimum Ampacity for Wire Sizing*
13.6
17.1
17.1
20.4
20.4
20.7
26.9
18.6
9.0
Minimum Wire Size (75 C Copper)
14
12
12
10
10
10
10
12
14
Maximum Wire Length (Ft.)
60
70
70
100
100
100
75
65
110
Cooling Capacity (Btuh)t
17,800
23,800
23,800
29,000
29,000
29,000
35,200
35,200
35,200
Rated Cooling Airflow (cfm)t
600
800
800
1100
1100
1100
1300
1300
1300
External Static Pressure (In.
water)t
0.10
0.10
0.10
0.15
0.15
0.15
0.15
0.15
0.15
ARI Sound Rating^
7.8
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
Rated Heating Input (cfm)
40,000
40,000
60,000
40,000
60,000
80,000
60,000
60,000
60,000
Output Capacity (Btuh)**
31,000
31,000
46,000
31,000
46,000
61,000
46,000
48,000
48,000
AFUE(%)**
77.5
77.5
77.5
77.5
77.5
77.5
77.5
—
—
Rated Heating Airflow (cfm)
658
658
740
658
740
987
987
987
987
Recommended Minimum Field-
Supplied Filter Size (Sq ln.)tt
Disposable-Type
288
384
384
528
624
Cleanable- or High-Capacity Type
192
256
256
352
416
(Applicable notes are listed below Table 4.)
Table 3—Specifications—Models 48N (Sizes MT036300 thru VT036600)
MODEL
48N
48N
48N
48N
48N
48N
48N
48N
48N
SIZE
MT036300
MT036500
MT036600
HT036300
HT036500
HT036600
VT036300
VT036500
VT036600
Unit Volts—Phase (60 Hz)
208/230—1 208/230—3
460—3
208/230—1 208/230—3
460—3
208/230—1 208/230—3
460—3
Operating Voltage Range
187—253
187—253
414—506
187—253
187—253
414—506
187—253
187—253
414—506
Unit Full Load Amps
21.2
14.6
7.7
22.4
16.8
8.5 '
22.4
16.8
8.5
Maximum Fuse Size (Amps)
40
25
15
40
25
15
40
25
15
Minimum Ampacity for Wire Sizing*
26.9
18.6
9,0
26.2
19.3
9.8
26.2
19.3
9.8
Minimum Wire Size (75 C Copper)
10
12
14
41
12
12
10
10
10
Maximum Wire Length (Ft.)
75
65
110
60
70
70
100
100
100
Cooling Capacity (Btuh)f
35,200
35,200
35,200
35,800
35,800
35,800
35,800
35,800
35,800
Rated Cooling Airflow (cfm)f
1300
1300
1300
1300
1300
1300
1300
1300
1300
External Static Pressure (In.
water)t
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
ARI Sound Ratingf:
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
Rated Heating Input (cfm)
80,000
80,000
80,00
100,0000
100,000
100,000
120,000
120,000
120,000
Output Capacity (Btuh)**
61,000
64,000
64,000
78,000
80,000
80,000
93,000
96,000
96,000
AFUE(%)**
77.5
__
—
77.5
—
—
77.5
—
—
Rated Heating Airflow (cfm)
987
987
987
1481
1481
1481
1367
1367
1367
Recommended Minimum Field-
Supplied Filter Size (Sq ln.)tt
Disposable-Type
624
624
Cleanable- or High-Capacity Type
416
416
(Applicable notes are listed below Table 4.)
Table 4—Specifications- - Models 48N (Sizes LT042300 thru HT042600)
MODEL
48N
48N
48N
48N
48N
48N
48N
48N
48N
SIZE
LT042300
LT042500
LT042600
MT042300
MT042500
MT042600
HT042300
HT042500
HT042600
Unit Volts—Phase (60 Hz)
208/230—1 208/230—1
460—3
208/230—1 208/230—3
460—3
208/230—1 208/230—3
460—3
Operating Voltage Range
187—253
187—253
414—506
187—253
187—253
414—506
187—253
187—253
414—506
Unit Full Load Amps
24.6
16.0
8.8
24.6
16.0
8.8
26.7
18.2
9.6
Maximum Fuse Size (Amps)
50
30
15
50
30
15
45
30
15
Minimum Ampacity for Wire Sizing*
31.1
20.4
10.3
31.1
2.4
10.3
31.7
21.1
11.1
Minimum Wire Size (75 C Copper)
8
10
14
8
10
14
10
12
14
Maximum Wire Length (Ft.)
95
100
100
95
100
100
75
65
110
Cooling Capacity (Btuh)t
41,500
41,500
41,500
41,500
41,500
41,500
41,500
41,500
41,500
Rated Cooling Airflow (cfm)f
1500
1500
1500
1500
1500
1500
1500
1500
1500
External Static Pressure (In.
water)t
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
ARI Sound Rating^:
7.8
8.0
8.0
8.0
8.0
8.0
8.2
8.2
8.2
Rated Heating Input (cfm)
60,000
60,000
60,00
80,000
80,000
80,000
100,000
100,000
100,000
Output Capacity (Btuh)**
46,000
48,000
48,000
61,000
64,000
64,000
78,000
80,000
80,000
AFUE(%)**
77.5
—
—
77.5
-
_
77.5
—
—
Rated Heating Airflow (cfm)
987
987
987
987
987
987
1481
1481
1481
Recommended Minimum Field-
Supplied Filter Size (Sq ln.)ft
Disposable-Type
720
720
Cleanable- or High-Capacity Type
480
480
*lf other than 75 C copper wire is used, determine size from unit ampacity and the National Electrical Code. Voltage drop of wire must be less than 2%
of unit rated voltage.
tRated in accordance with U.S. Government D.O.E. test procedures and/or ARI Standard 210.
tRated in accordance with ARI Standard 270.
**The capacity ratings of single-phase units are in accordance with U.S. Government D.O.E. test procedures and/or A.G.A. certification requirements. For
3-phase units, the efficiency rating is a product thermal efficiency rating determined under continuous operating conditions, independent of any
installed system.
ttRequired filter areas shown are based on the larger of the ARI-rated cooling airflow or the heating airflow at a velocity of 300 ft/min for disposable type
or 450 ft/min for high-capacity type. Air filter pressure drop must not exceed 0.08 in.-water.