Winco DSE3000 Series User Manual
Page 18
DSE Model 3000 Series Control and Instrumentation System Operators Manual
18
Part No. 057-086 3000 Series OPERATING MANUAL ISSUE 4 03/12/2009 ADM
5.2 GRAPHICAL DISPLAY
A 32x132 pixel LCD (35mm / 1.4”) is available for the display of generator instrumentation and alarm conditions.
The display is segmented into areas for instrumentation, unit, alarm icons and for Front Panel Editor (FPE) use.
When not in the Front Panel Editor (FPE) mode the FPE area of the display is used to display the currently active
configuration. The letter ‘M’ is displayed for main configuration active, the letter ‘A’ for alternative configuration
active.
5.3 VIEWING THE INSTRUMENTS
It is possible to scroll to display the different pages of information by repeatedly operating the scroll button
Once selected the page will remain on the LCD display until the user selects a different page or after an extended
period of inactivity, the module will revert to the status display.
When scrolling manually, the display will automatically return to the Status page if no buttons are pressed for the
duration of the configurable LCD Page Timer.
If an alarm becomes active while viewing the status page, the display shows the Alarms page to draw the operator’s
attention to the alarm condition.
Page order:-
Engine Speed
1500
rpm
Generator Volts
230
V
Generator Frequency
50.0
Hz
Engine Run Time
16.2
Battery Volts
13.8
V
Instrumentation
Icon
Units
FPE