Wilkerson ER2 User Manual

Page 3

background image

Position #4

ON PSIG / OFF Bar

(For LCD Units Only)

Position #3
4–20 mA Control

Position #2
INTERNAL Control

Position #5

Internal Sensor

Position #6

(Not Used)

Position #7

Range Selection

Position #1
0–10 VDC Control

Position #6

4–20 mA

Control Signal

Position #5

0–10 VDC

Control Signal

Position #4
Not Used

Position #3
0–10 VDC
Monitor Signal

Position #2
Common
Ground (-)

Position #1
VDC Supply (+)
Positive Pole

!

Figure 3A – Control Options

PLC Control with 0 – 10 VDC

PLC

Power Supply (+)

12 – 28 VDC (–)

Monitor Signal (+)

0 – 10 VDC (–)

Control Signal (+)

0 – 10 VDC (–)

Pressure Display

and

Internal Pressure Control

E

P

1

2

3

4

5

6

PLC Control with 4 – 20 mA

PLC

Power Supply (+)

12 – 28 VDC (–)

Monitor Signal (+)

0 – 10 VDC (–)

Control Signal (+)

4 – 20 mA (–)

Pressure Display

and

Internal Pressure Control

I

P

1

2

3

4

5

6

Internal Potentiometer

Power Supply (+)

12 – 28 VDC (–)

Monitor Signal (+)

0 – 10 VDC (–)

Pressure Display

and

Internal Pressure Control

E

P

1

2

3

4

5

6

Figure 3 – Terminal Block

Figure 2 – Jumper Connections

If using an external control circuit, connect the wires to
the appropriate terminals as follows:

(Refer to Figure 3)

Control signal:

- If using a 0–10 VDC control signal, connect the control wire

to position #5.

- If using a 4–20mA control signal, connect control wire to

position #6.

Monitor signal: (If used)

- Connect the external monitor feedback to position #3, this

outputs a 0–10 VDC that corresponds to a 1 VDC per 10%
of range.

Supply voltage and common ground:

- Connect the supply voltage positive pole (+) to position #1.

- Connect the common ground (–) for supply, control and

monitor signals to position #2.

If using the internal resistor control, wire the unit as follows:

Monitor signal: If monitor signal is not required, no
connection is required.

- Connect the external monitor feedback to position #3, this

outputs a 0–10 VDC that corresponds to a 1 VDC per 10%
of range.

Supply voltage and common ground:

- Connect the supply voltage positive pole (+) to position #1.

- Connect the common ground (–) for supply, and monitor

signals to position #2.

CAUTION: Reversing the polarity of the supply signal my
result in damage to the board.

Once the wires are properly located, secure the wires in the
terminal block and tighten the strain relief to secure the wires
and provide protection from the environment.