Connections when using with the vx-2000 system, Lead-acid battery lead-acid battery – Toa VX-200PS SA User Manual
Page 16

16
4. CONNECTIONS WHEN USING WITH THE VX-2000 SYSTEM
–
–
+
PS OUT
+
–
–
+
PS OUT
+
–
–
+
PS OUT
+
230V
50/60Hz
230V
50/60Hz
230V
50/60Hz
Lead-acid
Battery
Lead-acid
Battery
24V
MAX150A
BATTERY POWER IN
( )
( )
( )
230V
50/60Hz 240W
(–)
(–)
d
e
f
a
b
c
d
e
f
a
b
c
RJ45 male connector
VX-2000DS
Cat. 5 STP
Caution
The charging current from VX-2000DS is 5 A maximum.
Applicable Batteries: Panasonic LC-X1265PG/APG
230 V AC
220 V AC
50/60 Hz
230 V AC
220 V AC
50/60 Hz
230 V AC
220 V AC
50/60 Hz
230 V AC
220 V AC
50/60 Hz
To VX-2000SF
DS–SF LINK 1, 2 connectors
VX-200PS
VX-200PS
VX-200PS
To DC inputs of the following units.
VX-2000/2000SF, VP-2064/2122/2241/2421
6
1
5
4
3
2
6
1
5
4
3
2
DC POWER OUT (+) MAX 25A (DC 20V-40V)
PS IN (
+
) MAX 25A (DC20V-40V)
Turn the PS2 switch on when the
second VX-200PS unit is connected,
and the PS3 switch on when the
third unit is connected.
DETECT(VX-200PS)
OFF
ON
ON OFF
PS3
PS2
Cable:
AWG 6 – AWG 0 (1/0)
Cable:
AWG 14 – AWG 10
(line resistance within
10 mΩ/pair)
DS – SF
FUSE
LINK
DETECT(VX-200PS)
OFF
ON
ON OFF
THERMISTOR
PS3
PS2
1,2:PS1
PS IN
5,6:PS3
3,4:PS2
4.1. Connections between VX-2000DS and VX-200PS