12.12. VS-900MF Main Frame and PU-200 Power Transformer Connection

[Connection]
Connect as shown below using 2 parallel pair cables. Use cables with a sufficient current capacity and a
heavier gauge than AWG18. Two PU-200 units are required when using 3 or 4 VS-900RS cards.
Connect the backup power supply, if needed, to the VS-900MF's DC input as illustrated.

VS-900MF and power supply connection

VS-900MF

24 V DC

PU-200

To AC mains

PU-200

To AC mains

OUTPUT

20V AC 2.5A

20V AC 2.5A

OUTPUT

20V AC 2.5A

20V AC 2.5A

from PU-200

AC-IN

AC-IN

1

2

DC24V IN

G1 FG

from PU-200

AC-IN

AC-IN

3

4

Ferrite clamp*

Mount the ferrite clamp (supplied with the VS-900MF) on the cable in a way
that the cable is looped one turn as illustrated. (This countermeasure is for
complying with the CE marking and FCC requirements.)

*

Ferrite clamp
SFC-10