12.3. VS-900MS Master Station Interface Card Connection

12.3.1. Master Station and VS-900MS connection

• The VS-900MS can be interfaced with up to 2 MS-900 master stations.
• Because up to 2 VS-900MS cards can be mounted in the VS-900MF Main Frame, up to four master stations

can be connected per frame.

• A station address must be assigned to each connected MS-900 station. Set the station address at each MS-

900 station after switching ON the power.

[Station Address Setting]

Step 1. Set the Master Station's REGISTER switch to the ON position. The "Reg_mode" indication will be

displayed on the station screen.

Step 2. Press the [XFER] key.

Step 3. According to the following table, enter the station address 1 – 4 through the use of a numeric keypad.

VS-900MS

Line

Station Address

MS/AL Slot 1

1

1

2

2

MS/AL Slot 2

1

3

2

4

Step 4. Press the [PTT] key.

Step 5. Set the REGISTER switch to the OFF position to places the station in standby mode.