beautypg.com

Toa VS-900 User Manual

Page 44

background image

44

12.11.3. Connection to the VS-900TI

Connect each connector of the unit's Voice Lines 1 – 4 to the corresponding connector on the VS-900TI's CN
1 – 4. Pins No. 1 and 2 of each connector of Voice Lines 1 – 4 are for receiving ends, while pins No. 3 and 4
are for transmitting ends. Use 2 twisted pair cables for connection as shown below.

2 twisted pair cables

CN1

CN2

CN3

CN4

CN6

Line 1

Line 2

Line 3

Line 4

Data line
RS-485

A
B

GND
GND

VOICE LINE1

1

2

3

VS-900TI

Front view of
the circuit board

1 2 3 4

1
2
3
4

1
2
3
4

1
2
3
4

1
2
3
4

VS-900SC (figure of the inside of the front panel)

• For the VS-900TI, cut SJP of each line to be connected.

Line 1: LINK1-1 (SJP13) and LINK1-2 (SJP14)
Line 2: LINK2-1 (SJP15) and LINK2-2 (SJP16)
Line 3: LINK3-1 (SJP17) and LINK3-2 (SJP18)
Line 4: LINK4-1 (SJP19) and LINK4-2 (SJP20)

VS-900TI

LINK1-2 (SJP14)
LINK2-2 (SJP16)
LINK3-2 (SJP18)
LINK4-2 (SJP20)

LINK1-1 (SJP13)
LINK2-1 (SJP15)
LINK3-1 (SJP17)
LINK4-1 (SJP19)