Toa DP-K1 User Manual
Page 28

14.15. D-983 Remote Control Module (Optional)
Note: The design and specifications are subject to change without notice for improvement.
Contact Input
COM + Terminals 1 – 24: Open voltage 5 V DC, short-circuit current 5 mA,
RJ45 connector x 4
Preset Memory
Any preset memory can be recalled.
Selection
Control method: No-voltage make of over 100 ms or
no-voltage make single pulse of over 100 ms
Volume Control
Any input/output channel volume can be turned UP or DOWN.
Control method: 1 step variation with no-voltage make single pulse of over
100 ms
1 step continuous operation for every 70 ms for no-voltage
make of over 100 ms. Can be reset when at break.
Variable range: –∞ dB to 0 dB
Mute
Any output channel can be turned ON and OFF.
Control method: No-voltage make of over 100 ms or
no-voltage make single pulse of over 100 ms
Contact Output
COM + Terminals 1 – 16: No-voltage make contact,
contact capacity: 24 V DC, 100 mA,
RJ45 connector x 4
Finish
Panel: Pre-coated steel plate, black (30% glossy)
Dimensions
35 (w) x 119.5 (h) x 178.4 (d) mm
Weight
170 g
Control
133-02-00047-00
URL: http://www.toa.jp/