Connector connections

Step 1. Detach the unit's rear-mounted input/output

connector (removable terminal plug) from the unit.

Step 2. Loosen the terminal screw, then insert the cable.

Step 3. Retighten the terminal screw. (Pull on the cable to

ensure it is securely connected.)

Step 4. Remount the input/output connector to the unit.

Tip
Recommended slotted screwdriver type: Screwdriver with
blade that is 3 mm in width

11.2. Removable Terminal Plug Connection

Cautions
• Be sure to use shielded cables for audio signal lines.
• Avoid soldering stranded or shielded cable, as contact resistance may increase when the cable is tightened

and the solder is crushed, possibly resulting in an excessive rise in joint temperatures.

Cable end treatment

11.3. Ferrite Cable Clamp Attachment

(For D-972AE only)

To reduce electromagnetic noise, place the supplied
ferrite clamp over each digital output cable when
making a cable connection to the D-972AE Digital
Output Module.

Install one ferrite clamp per digital output cable.

D-972AE

Ferrite clamp
(Supplied with the D-972AE)

Loop the cable one turn.

model D-972AE

DIGITAL OUTPUT MODULE

1/2

3/4

AES/EBU

AES/EBU

DIGITAL OUT

Tightens

Terminal screw

Slotted screwdriver

Shielded cable

Removable
terminal plug

2

2

3

Loosens

7 mm

7 mm

20 mm

Solid or stranded cable

Shielded cable

Bit shape 3 mm