Removable terminal plug connection, Ferrite cable clamp attachment – Toa DP-K1 User Manual
Page 19

19
Connector connections
Step 1. Detach the unit's rear-mounted input/output
connector (removable terminal plug) from the unit.
Step 2. Loosen the terminal screw, then insert the cable.
Step 3. Retighten the terminal screw. (Pull on the cable to
ensure it is securely connected.)
Step 4. Remount the input/output connector to the unit.
Tip
Recommended slotted screwdriver type: Screwdriver with
blade that is 3 mm in width
11.2. Removable Terminal Plug Connection
Cautions
• Be sure to use shielded cables for audio signal lines.
• Avoid soldering stranded or shielded cable, as contact resistance may increase when the cable is tightened
and the solder is crushed, possibly resulting in an excessive rise in joint temperatures.
Cable end treatment
11.3. Ferrite Cable Clamp Attachment
(For D-972AE only)
To reduce electromagnetic noise, place the supplied
ferrite clamp over each digital output cable when
making a cable connection to the D-972AE Digital
Output Module.
Install one ferrite clamp per digital output cable.
D-972AE
Ferrite clamp
(Supplied with the D-972AE)
Loop the cable one turn.
model D-972AE
DIGITAL OUTPUT MODULE
1/2
3/4
AES/EBU
AES/EBU
DIGITAL OUT
Tightens
Terminal screw
Slotted screwdriver
Shielded cable
Removable
terminal plug
2
2
3
Loosens
7 mm
7 mm
20 mm
Solid or stranded cable
Shielded cable
Bit shape 3 mm