Tii ADX-SERIES User Manual
Tii Equipment
P/N 92209201 • Rev H•
8/28/2008
Warranty: If this unit fails during the warranty period, contact tii customer service to authorize return. Unit may be returned prepaid.
Model AD-SERIES Angle Driver Module with Surge Protection
ADX-SERIES Angle Driver Module without Surge Protection
Installation Note
Description
1. The AD-Series & ADX- Series Station
Protector modules may be installed in a wide
variety of station protector and network
interface housings.
2. The AD-Series & ADX- Series Station
Protector Modules provides one upper and
two lower ports per line for ease of wiring and
termination. It is equipped with a universal
grounding and mounting tab.
3. All ports utilize tool-less IDC rockers. The
upper ports accept 22-26 awg wire, the lower
ports terminate
18.5 ”F” drop - 24 awg wire.
Both ports are terminated by the driver bolt
mechanism.
4. The AD-Series & ADX- Series modules are
equipped with integral sealed test points for
ease of troubleshooting.
NOTE
National Electric Code Requirement. The
protector shall be installed per National
Electric Code ANSI/NFPA 70, Article
800, Section C, and shall meet all
applicable local safety codes.
These modules shall be installed in NID
enclosures evaluated to the requirement
of UL497.
Installation
1. The Angle Driver is delivered with a universal
grounding and mounting tab (See Figure 1). If
installing a new module into a NID, break
away the unwanted ground tab from the
module using a pair of pliers and discard (See
Figure 2). Install module on desired NID
ground post and secure with washer and nut.
Figure 1
Figure 2