INSTALLATION NOTE
1.0 DESCRIPTION
1.1 The TII 96-00-4 Series ADSL2+ Splitter Module
maintains a constant direct connection between
customer and central office service provider. The
Splitter Module is equipped with a customer test jack
(see Figure 1). The customer can insert the RJ-11
plug from a working telephone into this test jack to
assure a signal is received from the central office.
This is the only time the customer is disengaged (both
DSL and POTS service) from the central office.
2.0 WARRANTY
2.1 See TII Warranty. If this unit fails during the
warranty period, the factory should be requested
to authorize return. Return the unit prepaid. Units
that fail due to normal wear or abuse should be
discarded.
3.0 INSTALLATION
3.1 Remove the Splitter Module from plastic bag and
inspect; if damaged, replace with an undamaged
Splitter Module.
3.2 Hold the Splitter Module with the cover pivot side
on right.
3.3 Lower the pivot side edge inside the designated
installation cavity.
3.4 Engage the right end ledge under the catch. (See
Figure 2)
3.5 Push the left side end down until the latch snaps
closed.
4.0 WIRING
4.1 Three telephone voice (POTS) pairs and one DSL
line (DATA) can be connected to a single Splitter
Module. The customer has the option of installing
a #10 Master lock around the customer lock hasp
(see Figure 1).
4.2
When installing the first pair of customer
telephone wires, always begin with the bottom
terminating rockers (see Figure 1).
4.3 Do not strip wire insulation from wires to be
terminated to Splitter Module.
CAUTION: TO REDUCE THE RISK OF PERSONAL
INJURY, INSERT A RJ-11 PLUG INTO THE
CUSTOMER TEST JACK PRIOR TO MAKING ANY
WIRING CONNECTIONS .
4.4 Dress terminating wires (to protector) over NID
divider.
4.5 Insert and terminate TIP (GRN) & RING (RED)
wires into sealed IDC station protector (see
protector installation note for further details).
4.6 Open customer security cover on Splitter Module.
4.7 Lift all Splitter Module rockers to the open position
as shown (see Figure 1).
4.8 Dress wires around customer security cover.
4.9 Start wiring from the bottom left rocker.
4.10 Hold the customer voice telephone wires
between thumb and index finger (approx. 1/8”
separation between wires).
Figure 1
CUSTOMER LOCK HASP
PIVOT SIDE LEDGE
CUSTOMER TEST JACK
DATA ROCKER
VOICE CIRCUITS ONLY
TEST PORTS
ALL IDC'S ACCEPT 22-26 AWG SOLID WIRE
TIP SIDE GREEN
RING SIDE RED
TIP(GRN) & RING (RED)
TERMINATING WIRES
(TO PROTECTOR)