Tii 95-1-00-1 User Manual
Tii Equipment

P/N 92208101 • Rev D• 4/30/2008
Warranty: If this unit fails during the warranty period, contact tii customer service to authorize return. Unit may be returned prepaid.
Model 95-1-00-1 
Customer Bridge Module 
With Autojack 
Installation Note
Description
1. A Customer Bridge Module (CBM) maintains a
constant direct connection between customer 
and central office service provider. The CBM 
is equipped with a customer test jack. 
Customer can insert the RJ-11 plug from a 
working telephone into this test jack to assure 
a signal is received from the central office. 
This is the only time the customer is 
disengaged from the central office. 
Installation
Basic Operation
1. Inserting an R-J11 plug automatically
disconnects customer equipment and 
connects to the central office. This operation 
is usually performed during testing of the 
telephone line. 
2. By removing the RJ-11 plug, the customer is
automatically connected to the central office. 
This is the normal operating mode 
Installing CBM
1. Insert hinge side of module under tab on NID
enclosure. Dress wires to telco compartment. 
Pull back NID retainer tab, push down module 
until it snaps in place. Release retainer tab to 
hold module firmly in place. 
Wiring
1. A maximum of 4 telephone wires can be
attached to each wiring bridge screw. Insert 
wire through grommet. Strip insulation from 
wire. Pass wires behind hinge pin. Connect 
wire to color corresponding terminals. (NOTE: 
If customer wiring colors do not match Green 
and Red, inspect the first jack in premise. 
Determine which wire colors connect to Green 
and Red in jack.) 
2. Connect same wire colors to Green and Red
terminal screws in this housing. (Example: 
White/Blue stripe to Green; Blue/White stripe 
to Red). Wrap each clockwise between a 
washer on screw. 
Customer Security Cover
Customer Test Jack
Customer Lock
Hasp
Customer Premise
Connections
*RJ11 Plug is not required for normal operation