Fieldpilot, Installation of engage/disengage switch, Install the valve control cable – TeeJet FieldPilot Install AgChem 1803 User Manual
Page 19

www.teejet.com
18
FieldPilot
®
10. INSTALLATION OF ENGAGE/DISENGAGE SWITCH
Connect item
(A)
to the connector on the SCM harness labeled Remote Engage/Disengage. Install the push
button in a location that is easily accessible during operation of the machine. This switch
(A)
is not required
if the optional foot switch 32-04020 is used.
Figure 1-16: Engage/Disengage Switch
11. INSTALL THE VALVE CONTROL CABLE
Install the electronic valve control cable at the FieldPilot valve by attaching the DIN connectors to the
individual coils. Connect wire A to the left hand solenoid and wire B to the right hand solenoid.
NOTE: If the vehicle automatically steers the wrong way when tested, exchange the connector positions.
Route this cable under the cab and then into the cab through one of the exposed holes in the compartment
on the right rear of the cab. Secure the cable with wire ties as necessary.