beautypg.com

Fieldpilot, Installation of engage/disengage switch, Install the valve control cable – TeeJet FieldPilot Install AgChem 1803 User Manual

Page 19

background image

www.teejet.com

18

FieldPilot

®

10. INSTALLATION OF ENGAGE/DISENGAGE SWITCH

Connect item

(A)

to the connector on the SCM harness labeled Remote Engage/Disengage. Install the push

button in a location that is easily accessible during operation of the machine. This switch

(A)

is not required

if the optional foot switch 32-04020 is used.
Figure 1-16: Engage/Disengage Switch

11. INSTALL THE VALVE CONTROL CABLE

Install the electronic valve control cable at the FieldPilot valve by attaching the DIN connectors to the

individual coils. Connect wire A to the left hand solenoid and wire B to the right hand solenoid.
NOTE: If the vehicle automatically steers the wrong way when tested, exchange the connector positions.
Route this cable under the cab and then into the cab through one of the exposed holes in the compartment

on the right rear of the cab. Secure the cable with wire ties as necessary.